1635 S Saint Louis Ave
Chicago, IL · SINGLE PARCEL · Property ID 1623402012
1. What City of Chicago records show for this property
The property currently faces open violations with a court case pending.
The City issued the Jul 28, 2026 express repair permit (B200478921) for limited rear wood porch repairs, but the permit is currently suspended. At the latest City inspection on Feb 11, 2026, an inspector cited the porch system under code CN070024.
To move forward, the property owner needs to get the suspended permit reinstated, finish the rear porch repairs, and complete the front porch patching. The owner must arrange the required City porch inspections and attend the upcoming hearing on docket 26BT01566A, scheduled for Dec 9, 2026.
What will drive the cost (highest first): rear wood porch repair and railing rehabilitation, extra work if the contractor finds rotten or undersized framing, front concrete porch patching and crack repair, extra work if steel is exposed or the steps have moved. The 3 nearby properties that successfully fixed similar violations with building department permits are 3336 W Douglas Blvd, 3710 W Douglas Blvd and 1315 S Millard Ave (see section 7).
Key events in the last 3 years
| Date | Event | Details |
|---|---|---|
| Dec 9, 2026 | Court case 26BT01566A (hearing scheduled) | Upcoming hearing; last outcome: Continuance; fines $500. |
| Jul 28, 2026 | Permit #B200478921 issued | Permit – express permit program, status suspended, reported cost $7,500. Work: Limited repair (25% or less) for wood porch (open) (quantity: 2, location: rear of building). |
Register free to unlock contractor contacts, cost estimates from similar violations to negotiate with contractors, and an overall resolution plan that keeps your costs and stress low.
2. Violations and Suggested Resolution Plan
Violation 1 – Rear wood porch repair and railing rehabilitation
Inspector found (on Feb 11, 2026): CN070024 Repair porch system. 2 story masony building west elevation / grade to 1st floor /front concrete porch system - spalling / cracking in various locations. east elevation / grade to 2nd floor exterior wood porch system - entire porh is severely weathered and deteriorating covered in green like algae. d… Permit mentioned
Violation explanation: The City cited the rear two-story wood porch for severe weathering, loose cupping boards, protruding nails, and broken or missing guardrail balusters. The City specifically mandates a building permit and final inspection for these repairs.
Resolution plan: A City permit already covers this work: permit #B200478921 (permit – express permit program, issued Jul 28, 2026, status suspended) for "Limited repair (25% or less) for wood porch (open) (quantity: 2, location: rear of building)". A suggested path: complete the work under that permit and its City inspections, then ask the Department of Buildings to mark this violation complied; the permit number and inspection results may help at any hearing. A new permit is likely not needed for this item.
Violation 2 – Front concrete porch patching and crack repair
Inspector found (on Feb 11, 2026): CN070024 Repair porch system. 2 story masony building west elevation / grade to 1st floor /front concrete porch system - spalling / cracking in various locations. east elevation / grade to 2nd floor exterior wood porch system - entire porh is severely weathered and deteriorating covered in green like algae. d… Permit mentioned
Violation explanation: The City cited surface spalling and cracking on the front concrete porch steps from grade to the first floor. This may need to be patched and sealed to prevent water penetration and tripping hazards.
Resolution plan: A City permit already covers this work: permit #B200478921 (permit – express permit program, issued Jul 28, 2026, status suspended) for "Limited repair (25% or less) for wood porch (open) (quantity: 2, location: rear of building)". A suggested path: complete the work under that permit and its City inspections, then ask the Department of Buildings to mark this violation complied; the permit number and inspection results may help at any hearing. A new permit is likely not needed for this item.
3. Permits
Violations where the City's own text mentions a permit, or where similar properties pulled a permit to fix the same violation, with whether architect drawings are needed, the City permit fee and the typical time to get the permit (preparation included).
| Violation | Permit mentioned in violation | Similar properties pulled a permit | Architect drawings | City permit fee | Typical time to get the permit |
|---|---|---|---|---|---|
| 1. Rear wood porch repair and railing rehabilitation | Yes | Yes 3336 W Douglas Blvd fixed the same violation with a permit (May 8, 2024) | Not needed (express permit on file) | $302–$600 | Already issued: permit #B200478921 (Jul 28, 2026, suspended) |
| 2. Front concrete porch patching and crack repair | Yes | Yes 3336 W Douglas Blvd fixed the same violation with a permit (May 8, 2024) | Not needed (express permit on file) | About $600–$4,239 (fees paid on 301 similar permits) | Already issued: permit #B200478921 (Jul 28, 2026, suspended) |
Fee source: the repair rule's City fee, or the middle half of City fees actually paid on similar permits in the last 3 years (City of Chicago building permits data). City of Chicago Department of Buildings, Building Permit Fee Tables (2025 edition). Confirm the current schedule with the Department of Buildings before applying.
4. Latest City inspections
The last 3 City inspections on record for this property, what the inspector found, and where each cited item stands now. The City's data lists only inspections that found at least one violation; inspections that passed with nothing cited are not listed.
Feb 11, 2026 – Complaint, Conservation bureau
Inspection #14766880
Result: Failed: the inspector found problems. The City still lists 1 of 1 cited item.
| Code | Violation | Inspector notes |
|---|---|---|
| CN070024 | Repair porch system | Exterior:e :east & west elevations / grade to 2nd floor: 2 story masony building west elevation / grade to 1st floor /front concrete porch system - spalling / cracking in various locations. east elevation / grade to 2nd floor exterior wood porch system - entire porh is severely weathered and deteriorating covered in green like algae. deck boards / treads - loose, cracking and cupping fastened with rusting protruding nails in various locations. handrails / guardrails - broken / missing balusters loose, cracking and missing proper hardware in various locations. permit is required for all repairs to the exterior wood porch system. all repairs are subje |
Jun 17, 2021 – Complaint, Ventilation bureau
Inspection #13586232 · older than 3 years, shown for context
Result: Failed: the inspector found problems. The City still lists 4 of 4 cited items.
| Code | Violation | Inspector notes |
|---|---|---|
| VT1010 | Arrange completed permit insp. | 1635 s st louis av: Inspection required 18-28-106.1 arrange for inspection |
| 199029 | Open type violation | (vt 2031) 13-16-070 workmanship to meet intent of building provisions of this code |
| 199029 | Open type violation | (vt 7011) carbon monoxide detectors 18-28-71 carbon monoxide detectors shall be installed in accordance with sections 18-9-908.7 |
| VT4010 | Provide outside air supply | 18-28-403.1 prohibited exhaust no air from boiler room in which such air might be contaminated by smoke |
Jun 4, 2021 – Complaint, Ventilation bureau
Inspection #13573776 · older than 3 years, shown for context
Result: Failed: the inspector found problems. The City still lists 3 of 3 cited items.
| Code | Violation | Inspector notes |
|---|---|---|
| VT1010 | Arrange completed permit insp. | 1635 s st louis av: Arrange mechanical ventilation or warm air heating system final inspection when work completed code 18-28-106.1 |
| VT3020 | Maintain mech. vent system | Maintain mechanical ventilation system code 18-28-102 |
| CN194019 | Repair or replace | Repair or replace exhaust flue and water heater exhaust flue 2nd flr |
What it takes to finish the open permit
Typical City inspections and sign-offs needed to finish the work each open permit was issued for. These are typical steps: the City's open data does not show which inspections have already passed, so check the permit's inspection history with the Department of Buildings.
Permit #B200478921 – Express permit (repairs) (Suspended, issued Jul 28, 2026)
- Get the permit reinstated: The permit is suspended; work and inspections can continue only after the City reinstates it.
- Porch footing inspection: New or replaced porch footings checked before concrete is poured.
- Porch framing and final inspection: Porch framing, guards and stairs checked, then a final inspection.
- Final inspection (if scheduled): Repairs like roofing, masonry and tuckpointing often get a single final inspection, or none.
- Permit marked complete: The City shows the permit as COMPLETE.
5. Court cases (City of Chicago Department of Administrative Hearings)
| Docket | Status | Last / next hearing | Outcome | Fines imposed |
|---|---|---|---|---|
| 26BT01566A | Upcoming hearing | Dec 9, 2026 (upcoming) | Continuance | $500 |
From the City's Administrative Hearings data. Fines appear only after a case is decided.
6. Estimated costs
These are suggestions to help plan the work, not quotes. Verify every figure independently with licensed contractors and the City of Chicago Department of Buildings.
Rear wood porch repair and railing rehabilitation requires $2,125 to $3,675 in materials, with estimated labor between 70 and 130 hours for a porch contractor. Only if the contractor finds rotten or undersized framing, extra work ranges from $2,430 to $4,510, requiring 120 to 220 hours of labor.
Front concrete porch patching and crack repair by a concrete or masonry contractor involves $200 to $675 in materials and 10 to 24 hours of labor. Only if steel is exposed or the steps have moved, extra work ranges from $350 to $850, requiring 24 to 48 hours of labor.
Materials – 1. Rear wood porch repair and railing rehabilitation
Directional only. Final sizes and quantities come from a site visit. Labor: about 70–130 hours.
| Item | Typical specification | How much | Fixes | Material cost |
|---|---|---|---|---|
| Repair scope (as cited) | ||||
| Decking | 5/4×6 or 2×6 pressure-treated boards | About 440 linear ft (≈200 sq ft over 2 levels) | Loose, cracked deck boards | $770–$1,210 |
| Deck fasteners | Coated or stainless deck screws (no nails) | About 700 screws | Rusting nails sticking out | $90–$220 |
| Stair treads | 2×12 pressure-treated, or two 5/4×6 | One per step; grade to 2nd floor is often 20–24 steps | Loose, cracking treads | $400–$660 |
| Guard rails | 2×4 / 2×6 pressure-treated top and bottom rails | About 140 linear ft (2 × open sides + stairs) | Loose guardrails | $180–$350 |
| Balusters | 2×2 pressure-treated, under 4 in apart | About 3 per linear ft of guard (≈210) | Broken or missing balusters | $525–$945 |
| Guard post hardware | ½-in galvanized through-bolts, nuts and washers | 2 per guard post (≈24) | Missing hardware | $100–$170 |
| Misc. hardware | Galvanized structural screws, flashing tape | Lot | Structural fastenings | $60–$120 |
| If the architect finds the framing deficient (Only if the contractor finds rotten or undersized framing) | ||||
| Floor joists | 2×8 or 2×10 pressure-treated, sized from the City porch tables | Per architect (≈30 pieces) | Weathered framing | $750–$1,350 |
| Posts and bases | 6×6 pressure-treated on galvanized post bases | Per architect (≈6) | Weathered framing | $510–$930 |
| Footings | Concrete piers below frost depth (42 in) | One per post | Posts without footings | $270–$480 |
| Bracing | Pressure-treated knee braces, bolted | At posts, each level | Side-to-side stability | $150–$300 |
| Stair stringers and support | 2×12 stringers, mid-span post and footing | Per flight | Long stair support | $250–$450 |
| Beams, ledger and connectors | Joist hangers, masonry anchors, bolts | Per drawings | Attachment to building | $500–$1,000 |
Not included: architect's drawings and site visit, City permit fee, and contractor labor charges.
Materials – 2. Front concrete porch patching and crack repair
Directional only. Final sizes and quantities come from a site visit. Labor: about 10–24 hours.
| Item | Typical specification | How much | Fixes | Material cost |
|---|---|---|---|---|
| Patch and seal (as cited) | ||||
| Repair mortar | Polymer-modified concrete repair mortar | 4–10 bags (50 lb) | Spalling surface | $80–$350 |
| Bonding agent | Concrete bonding agent | 1 gallon | Spalling surface | $25–$45 |
| Crack sealant | Polyurethane or self-leveling concrete sealant | 3–6 tubes | Cracks | $25–$90 |
| Sealer | Penetrating silane/siloxane sealer | 1–2 gallons | Slows future spalling | $40–$110 |
| Consumables | Wire brush, chisel, trowels | Lot | Surface preparation | $30–$80 |
| If steps must be replaced (Only if steel is exposed or the steps have moved) | ||||
| Concrete | Ready-mix or bagged 4,000 psi | ≈1–2 cu yd | Failed steps | $250–$600 |
| Rebar and forms | #4 rebar, form lumber, stakes | Lot | Exposed steel | $100–$250 |
Not included: contractor labor charges, and a permit fee if steps are replaced.
7. Nearby Properties that Resolved Similar Violations
The closest properties cited for the same kind of violation that got a matching building department permit and were later marked complied by the City.
3336 W Douglas Blvd – 0.4 mi away
Similar to violation 1, 2 on this page (porch).
| Date | Code | Violation | Inspector notes | Status |
|---|---|---|---|---|
| Jul 28, 2023 | CN070024 | Repair porch system | WEST AND SOUTHWEST ELEVATIONS / 2 REAR PORCH SYSTEMS / GRADE TO 3RD FLOOR / 1334 -1340 S CHRISTIANA / 3334 - W DOUGLAS6X6 COLUMNS - SEVERELY WEATHERED, CRACKING AND TWISTING.TREADS - SEVERELY WEATHER, LOOSE CRACKING AND CUPPING THROUGHOUT FASTENED WITH RUSTING PROTRUDING NAILS. WINDER AT 2ND TO 3RD FLOOR BROKEN CORNER SECTION.DECK BOARDS - SEVERELY WEATHERED, LOOSE CRACKING AND CUPPING. PERMIT RE | Complied Aug 29, 2024 |
How it was resolved: permit 101049781 issued May 8, 2024 for "Remove & replace exist. porches"; reported project cost $48,000 (materials and labor). Contractor: CONTRACTOR-GENERAL CONTRACTOR: FRACKIEL BUILDERS, INCORPORATED (CHICAGO 60630-). Architect: GIBAS, PAWEL S (ROSELLE 60172). Expediter: EXPEDITOR: FRACKIEL BUILDERS, INC. (CHICAGO 60630-). No court case was recorded.
3710 W Douglas Blvd – 0.4 mi away
Similar to violation 1, 2 on this page (porch).
| Date | Code | Violation | Inspector notes | Status |
|---|---|---|---|---|
| Feb 15, 2023 | CN070024 | Repair porch system | REAR ENCLOSED TWO-STORY WOODEN PORCH /PORCH - LEANING AWAY FROM HOUSE. /FOUNDATIONS - 4X4 POSTS SITTING ON GROUND AND CONCRETE SLABS. /JOISTS - 2X6 SPANNING 6 FEET AND NAILED ONLY WITH SOME JOISTS DETACHED. /RAILS - LOOSE AND DETATCHED. /STRINGERS - NAILED ONLY AND CRACKING. /FLOOR BOARDS - BROKEN UNDER STRINGER AT LANDING AND SINKING. PLANS AND PERMITS REQUIRED TO REPAIR PORCH SYSTEM. SUBJECT TO | Complied Aug 1, 2025 |
How it was resolved: permit 101061064 issued Jan 27, 2025 for "Self-cert 2019 cbrc: rebuild enclosed rear porch and stairs per plans. new lighting fixtures for the enclosed porch. architectural and electrical disciples are involved. (occupancy r-5; type iiia construction)"; reported project cost $10,000 (materials and labor). Contractor: CONTRACTOR-GENERAL CONTRACTOR: JAZMEN CONSTRUCTION GROUP LLC (CHICAGO 60615). Architect: YUNG, EDWARD M (PALATINE 60074). No expediter was recorded. No court case was recorded.
1315 S Millard Ave – 0.5 mi away
Similar to violation 1, 2 on this page (porch).
| Date | Code | Violation | Inspector notes | Status |
|---|---|---|---|---|
| Apr 29, 2022 | CN070024 | Repair porch system | 1315 S./ REAR OF BUILDING / 2 STORY PORCH - COLUMNS OVER NOTCHED, WITH FIRE CUTS AND BEAM, SPLICE CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY. BEAMS SCABBED TO COLUMNS AT FIRE CUTS. LOOSE FLOOR BOARDS, RUSTED HARDWARE AND NAILS, INADEQUATE HALF CUTS AND LOOSE GAURDRAILS. PLANS AND PERMITS REQUIRED FOR REPAIRS. | Complied Jan 18, 2023 |
How it was resolved: permit 100987375 issued Oct 19, 2022 for "Remove existing back porch and replaced with new back porch per new plan. exist'g foundation wall remains."; reported project cost $25,000 (materials and labor). Contractor: CONTRACTOR-GENERAL CONTRACTOR: 1ST CHICAGOLAND BUILDERS AND RENOVATORS LLC (CHICAGO 60639-). Architect: FANG, HUNG CHUN (BARTLETT 60103-). No expediter was recorded. Court: case 22BT01593A (Closed - not liable).
8. Repair diagrams
8.1 Rear wood porch repair and railing rehabilitation (violation 1): what was cited, and what a compliant fix typically looks like
Illustration of a typical 2-level rear porch on a masonry building. Not drawn from measurements of this property.
Today, as cited
- Deck boards loose, cracked and cupped; rusting nails sticking out
- Balusters broken or missing
- Guardrails loose, hardware missing
- Stair treads loose and cracking
- Framing weathered, covered in algae
Typical compliant fix
- New pressure-treated decking fastened with coated or stainless screws (fixes 1)
- Guard at least 42 in high, balusters close enough to stop a 4-in sphere (fixes 2)
- Guard posts through-bolted to the framing (fixes 3)
- New treads on solid stringers (fixes 4)
- Posts on metal bases over concrete footings below frost depth — if the architect calls for it (fixes 5)
- Knee braces for side-to-side stability; joists sized by the architect (fixes 5)
- Beam or ledger bolted to the masonry wall as the drawings specify
What a finished repair looks like


8.2 Front concrete porch patching and crack repair (violation 2): what was cited, and what a compliant fix typically looks like
Illustration of typical front concrete steps on a masonry building. Not drawn from measurements of this property.
Today, as cited
- Cracks through the landing and steps
- Spalling: surface and edges breaking away
- Exposed steel at step edges (check on site)
Typical compliant fix
- Loose concrete removed; surface rebuilt with polymer-modified repair mortar (fixes 2)
- Cracks routed and filled with concrete sealant (fixes 1)
- Penetrating sealer on all surfaces to slow future spalling (shown blue)
- If steel is exposed or steps have moved: replace those steps with new reinforced concrete (fixes 3)
9. Violation history (all years)
Some of this historical data may be stale or no longer applicable. Please verify with the City of Chicago Department of Buildings and the courts as applicable.
Violations (10)
| Date | Code | Violation | Inspector notes |
|---|---|---|---|
| Feb 11, 2026 | CN070024 | Repair porch system | 2 story masony building west elevation / grade to 1st floor /front concrete porch system - spalling / cracking in various locations. east elevation / grade to 2nd floor exterior wood porch system - entire porh is severely weathered and deteriorating covered in green like algae. deck boards / treads |
| Jun 17, 2021 | 199029 | Open type violation | (vt 7011) carbon monoxide detectors 18-28-71 carbon monoxide detectors shall be installed in accordance with sections 18-9-908.7 |
| Jun 17, 2021 | VT1010 | Arrange completed permit insp. | Inspection required 18-28-106.1 arrange for inspection |
| Jun 17, 2021 | VT4010 | Provide outside air supply | 18-28-403.1 prohibited exhaust no air from boiler room in which such air might be contaminated by smoke |
| Jun 17, 2021 | 199029 | Open type violation | (vt 2031) 13-16-070 workmanship to meet intent of building provisions of this code |
| Jun 4, 2021 | CN194019 | Repair or replace | Repair or replace exhaust flue and water heater exhaust flue 2nd flr |
| Jun 4, 2021 | VT3020 | Maintain mech. vent system | Maintain mechanical ventilation system code 18-28-102 |
| Jun 4, 2021 | VT1010 | Arrange completed permit insp. | Arrange mechanical ventilation or warm air heating system final inspection when work completed code 18-28-106.1 |
| Sep 13, 2017 | EL0011 | Add branch circuits | Ease overloaded circuits in basement |
| Sep 13, 2017 | EL0004 | Defective feeder | Seperate basement circuits from arc faults |
Older court cases (3)
| Docket | Last hearing | Outcome | Fines |
|---|---|---|---|
| 21BT01158A | Apr 6, 2022 | Non-Suit | $0 |
| 21BT01128A | Apr 6, 2022 | Non-Suit | $0 |
| 18BT00466A | Jul 16, 2018 | Non-Suit | $0 |
Permits (2)
| Permit | Issued | Type | Work |
|---|---|---|---|
| B200478921 | Jul 28, 2026 | Permit – express permit program | Limited repair (25% or less) for wood porch (open) (quantity: 2, location: rear of building). |
| B100763824 | May 24, 2018 | Permit – express permit program | Install ark fault breakers for basement bedrooms only. |